Product application: applicable to pressure difference measurement and control in oil,
chemical, power plant, urban water supply and hydrological exploration.
pressure range:0-3.5MPa;
accuracy:0.25%FS;
Output signal: 4-20m ADC
24-hour national online service:
025-84363968
Power supply: 2-wire 15~28VDC 3-wire 15~28VDC
Electric connection: plug connection or Φ7.2mm 7-pin cable
Insulation resistor: 100MΩ,50VDC
Construction Material
Diaphragm: stainless steel 316L
Filled liquid: silicon oil
Shock effect: ≤1% at 3gRMS, 30~2000Hz
Media: liquid or gas which is compatible with construction material
Pressure range | -0.1MPa…0~20kPa…3.5MPa |
Overpressure | 1.5 times FS or 110MPa (min.value is valid) |
Power supply | 1.5mADC |
Signal | ≥70mVDC(0~20kPa,≥50mVDC) |
Accuracy | ±0.1%FS(min.) ±0.25%FS(typ.) ±0.5%FS(max.) |
Long-term stability | ±0.3%FS/year |
Compensation temp. | 0℃~50℃ |
Operation temp. | -10℃~80℃ |
Storage temp. | -40℃~100℃ |
Zero temp. coefficient | ±0.02%FS/℃(typ.) ±0.04%FS/℃(max.) |
FS temp. coefficient | ±0.02%FS/℃(typ.) ±0.04%FS/℃(max.) |
Housing | Stainless steel 1Cr18Ni9Ti |
Diaphragm | Stainless steel 316L |
O-ring | Viton |
Cable | Polythene |
Response time(10%~90%) | ≤1ms |
Insulation resistance | 100MΩ,100VDC |
Production | IP65(cable connection) |
1. We suggest to install tri-valve between the measured point and transmitter to protect the media adding on transmitter’s positive and negative cavities slowly;
3. Please pay attention that the static pressure should be less than 20Mpa, transmitter positive and negative cavity should be in the rating pressure range;
5. Digital indicator information, please refer to MPR300 datasheet;
RECOMMEND
9
南京冉控科技有限公司 版權(quán)所有 蘇ICP備18060422號(hào)-1 Address:Nanjing Qixia Maqun Science Park